| OID | 1.3.6.1.2.1.16.19.5 |
| Module | RMON2-MIB (CISCO) |
| Nom | probeResetControl |
| Acces | readwrite |
| Status | current |
| Description | Setting this object to warmBoot(2) causes the device to
restart the application software with current configuration
parameters saved in non-volatile memory. Setting this
object to coldBoot(3) causes the device to reinitialize
configuration parameters in non-volatile memory to default
values and restart the application software. When the device
is running normally, this variable has a value of
running(1). |
| Syntaxe | Enumeration (1-running, 2-warmBoot, 3-coldBoot) |
| Module | RMON2-MIB (ietf) |
| Nom | probeResetControl |
| Acces | readwrite |
| Status | current |
| Description | Setting this object to warmBoot(2) causes the device to
restart the application software with current configuration
parameters saved in non-volatile memory. Setting this
object to coldBoot(3) causes the device to reinitialize
configuration parameters in non-volatile memory to default
values and to restart the application software. When the device
is running normally, this variable has a value of
running(1). |
| Syntaxe | Enumeration (1-running, 2-warmBoot, 3-coldBoot) |
| Module | RMON2-MIB (Force10-9.14.2.1) |
| Nom | probeResetControl |
| Acces | readwrite |
| Status | current |
| Description | Setting this object to warmBoot(2) causes the device to
restart the application software with current configuration
parameters saved in non-volatile memory. Setting this
object to coldBoot(3) causes the device to reinitialize
configuration parameters in non-volatile memory to default
values and to restart the application software. When the device
is running normally, this variable has a value of
running(1). |
| Syntaxe | Enumeration (1-running, 2-warmBoot, 3-coldBoot) |
| Module | RMON2-MIB (FS) |
| Nom | probeResetControl |
| Acces | readwrite |
| Status | current |
| Description | Setting this object to warmBoot(2) causes the device to
restart the application software with current configuration
parameters saved in non-volatile memory. Setting this
object to coldBoot(3) causes the device to reinitialize
configuration parameters in non-volatile memory to default
values and restart the application software. When the device
is running normally, this variable has a value of
running(1). |
| Syntaxe | Enumeration (1-running, 2-warmBoot, 3-coldBoot) |