MIB Discovery
1930 modules enregistrés
Chemin
MIX : 1 (iso). 0. 8802. 1. 1. 2 (lldpMIB). 1 (lldpObjects). 1 (lldpConfiguration). 5 (lldpNotificationInterval)
OID : 1.0.8802.1.1.2.1.1.5
TXT : iso. 0. 8802. 1. 1. lldpMIB. lldpObjects. lldpConfiguration. lldpNotificationInterval
Enfants
Pas d'enfants disponibles pour cet OID
Détails
OID1.0.8802.1.1.2.1.1.5
Module LLDP-MIB (CISCO)
NomlldpNotificationInterval
Accesreadwrite
Statuscurrent
DescriptionThis object controls the transmission of LLDP notifications. the agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. An NMS should periodically check the value of lldpStatsRemTableLastChangeTime to detect any missed lldpRemTablesChange notification-events, e.g. due to throttling or transmission loss. If notification transmission is enabled for particular ports, the suggested default throttling period is 5 seconds. The value of this object must be restored from non-volatile storage after a re-initialization of the management system.
Uniteseconds
SyntaxeInteger32 (5...3600)
Module LLDP-MIB (DELL)
NomlldpNotificationInterval
Accesreadwrite
Statuscurrent
DescriptionThis object controls the transmission of LLDP notifications. the agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. An NMS should periodically check the value of lldpStatsRemTableLastChangeTime to detect any missed lldpRemTablesChange notification-events, e.g. due to throttling or transmission loss. If notification transmission is enabled for particular ports, the suggested default throttling period is 5 seconds. The value of this object must be restored from non-volatile storage after a re-initialization of the management system.
Uniteseconds
SyntaxeInteger32 (5...3600)
Module LLDP-MIB (Alcatel)
NomlldpNotificationInterval
Accesreadwrite
Statuscurrent
DescriptionThis object controls the transmission of LLDP notifications. the agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. An NMS should periodically check the value of lldpStatsRemTableLastChangeTime to detect any missed lldpRemTablesChange notification-events, e.g. due to throttling or transmission loss. If notification transmission is enabled for particular ports, the suggested default throttling period is 5 seconds. The value of this object must be restored from non-volatile storage after a re-initialization of the management system.
Uniteseconds
SyntaxeInteger32 (5...3600)
Module LLDP-MIB (Force10-9.14.2.1)
NomlldpNotificationInterval
Accesreadwrite
Statuscurrent
DescriptionThis object controls the transmission of LLDP notifications. the agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. An NMS should periodically check the value of lldpStatsRemTableLastChangeTime to detect any missed lldpRemTablesChange notification-events, e.g. due to throttling or transmission loss. If notification transmission is enabled for particular ports, the suggested default throttling period is 5 seconds. The value of this object must be restored from non-volatile storage after a re-initialization of the management system.
Uniteseconds
SyntaxeInteger32 (5...3600)
Module LLDP-MIB (FS)
NomlldpNotificationInterval
Accesreadwrite
Statuscurrent
DescriptionThis object controls the transmission of LLDP notifications. the agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. An NMS should periodically check the value of lldpStatsRemTableLastChangeTime to detect any missed lldpRemTablesChange notification-events, e.g. due to throttling or transmission loss. If notification transmission is enabled for particular ports, the suggested default throttling period is 5 seconds. The value of this object must be restored from non-volatile storage after a re-initialization of the management system.
Uniteseconds
SyntaxeInteger32 (5...3600)
Module LLDP-MIB (Nexans)
NomlldpNotificationInterval
Accesreadwrite
Statuscurrent
DescriptionThis object controls the transmission of LLDP notifications. the agent must not generate more than one lldpRemTablesChange notification-event in the indicated period, where a 'notification-event' is the transmission of a single notification PDU type to a list of notification destinations. If additional changes in lldpRemoteSystemsData object groups occur within the indicated throttling period, then these trap- events must be suppressed by the agent. An NMS should periodically check the value of lldpStatsRemTableLastChangeTime to detect any missed lldpRemTablesChange notification-events, e.g. due to throttling or transmission loss. If notification transmission is enabled for particular ports, the suggested default throttling period is 5 seconds. The value of this object must be restored from non-volatile storage after a re-initialization of the management system.
Uniteseconds
SyntaxeInteger32 (5...3600)