MIB Discovery
1930 modules enregistrés
Chemin
MIX : 1 (iso). 3 (org). 111. 2. 802. 1. 1 (ieee802dot1mibs). 18 (ieee8021CnMib). 1 (ieee8021CnMIBObjects). 8 (ieee8021CnRpGroupTable)
OID : 1.3.111.2.802.1.1.18.1.8
TXT : iso. org. 111. 2. 802. 1. ieee802dot1mibs. ieee8021CnMib. ieee8021CnMIBObjects. ieee8021CnRpGroupTable
Enfants
Détails
OID1.3.111.2.802.1.1.18.1.8
Module IEEE8021-CN-MIB (DELL)
Nomieee8021CnRpGroupTable
Statuscurrent
DescriptionEach row in this table supplies values for one or more Reaction Points (RPs). This table is indexed by component, port (interface), and an arbitrary RP index. Creating an entry in ieee8021CnCompntPriTable can create an entry in this table, with the default values, on all ports in the end station. An end station can have more than one RP for the same Congestion Notification Priority Value (CNPV), so creating an entry in ieee8021CnCompntPriTable can create multiple entries in this table. Because each port in a bridge component or end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. Deleting the an entry in ieee8021CnCompntPriTable for a CNPV passing through the RP controlled by this entry deletes entries on some or all of the ports in the end station. Because each port in an end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. The relationship between ieee8021CnRpgIdentifier values and RPs is an implementation dependent matter. The contents of this table SHALL be maintained across a restart of the system, except as noted in the description of ieee8021CnRpgIfIndex.
Module IEEE8021-CN-MIB (Alcatel)
Nomieee8021CnRpGroupTable
Statuscurrent
DescriptionEach row in this table supplies values for one or more Reaction Points (RPs). This table is indexed by component, port (interface), and an arbitrary RP index. Creating an entry in ieee8021CnCompntPriTable can create an entry in this table, with the default values, on all ports in the end station. An end station can have more than one RP for the same Congestion Notification Priority Value (CNPV), so creating an entry in ieee8021CnCompntPriTable can create multiple entries in this table. Because each port in a bridge component or end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. Deleting the an entry in ieee8021CnCompntPriTable for a CNPV passing through the RP controlled by this entry deletes entries on some or all of the ports in the end station. Because each port in an end station can have a different relationship between CNPVs and RPs, the entries created or deleted on each port can be different. The relationship between ieee8021CnRpgIdentifier values and RPs is an implementation dependent matter. The contents of this table SHALL be maintained across a restart of the system, except as noted in the description of ieee8021CnRpgIfIndex.