OID | 1.3.6.1.2.1.10.134.2.1.1.1.1 |
Module | ETHER-WIS (CISCO) |
Nom | etherWisPathCurrentStatus |
Acces | readonly |
Status | current |
Description | This variable indicates the current status of the
path payload with a bit map that can indicate multiple
defects at once. The bit positions are assigned as
follows:
etherWisPathLOP(0)
This bit is set to indicate that an
LOP-P (Loss of Pointer - Path) defect
is being experienced. Note: when this
bit is set, sonetPathSTSLOP MUST be set
in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathAIS(1)
This bit is set to indicate that an
AIS-P (Alarm Indication Signal - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSTSAIS MUST be
set in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathPLM(1)
This bit is set to indicate that a
PLM-P (Payload Label Mismatch - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSignalLabelMismatch
MUST be set in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathLCD(3)
This bit is set to indicate that an
LCD-P (Loss of Codegroup Delination - Path)
defect is being experienced. Since this
defect is detected by the PCS and not by
the path layer itself, there is no
corresponding bit in sonetPathCurrentStatus. |
Syntaxe | Bits (0-etherWisPathLOP, 1-etherWisPathAIS, 2-etherWisPathPLM, 3-etherWisPathLCD) |
Module | ETHER-WIS (ietf) |
Nom | etherWisPathCurrentStatus |
Acces | readonly |
Status | current |
Description | This variable indicates the current status of the
path payload with a bit map that can indicate multiple
defects at once. The bit positions are assigned as
follows:
etherWisPathLOP(0)
This bit is set to indicate that an
LOP-P (Loss of Pointer - Path) defect
is being experienced. Note: when this
bit is set, sonetPathSTSLOP MUST be set
in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathAIS(1)
This bit is set to indicate that an
AIS-P (Alarm Indication Signal - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSTSAIS MUST be
set in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathPLM(1)
This bit is set to indicate that a
PLM-P (Payload Label Mismatch - Path)
defect is being experienced. Note: when
this bit is set, sonetPathSignalLabelMismatch
MUST be set in the corresponding instance of
sonetPathCurrentStatus.
etherWisPathLCD(3)
This bit is set to indicate that an
LCD-P (Loss of Codegroup Delination - Path)
defect is being experienced. Since this
defect is detected by the PCS and not by
the path layer itself, there is no
corresponding bit in sonetPathCurrentStatus. |
Syntaxe | Bits (0-etherWisPathLOP, 1-etherWisPathAIS, 2-etherWisPathPLM, 3-etherWisPathLCD) |