Description | The WWN that is configured on this switch to be used as
the name of this Fabric when the value of t11FamEnable is
'false'.
If the value of t11FamEnable is 'true', this value is not
used.
Fibre Channel requires that:
a) all switches in an operational Fabric be
configured with the same Fabric name; and
b) each Fabric have a unique Fabric name.
If either of these is violated, either by switches within a
single Fabric being configured with different Fabric names,
or by multiple Fabrics that share management applications
or interact in other ways having the same Fabric name,
then the behavior of the switches and associated management
functions is not specified by Fibre Channel or Internet
standards.
For the persistence of values across reboots, see the
MODULE-IDENTITY's DESCRIPTION clause. |