OID | 1.3.6.1.2.1.138.1.4.1.1.9 |
Module | ISIS-MIB (CISCO) |
Nom | isisCircLevelHelloTimer |
Acces | readwrite |
Status | current |
Description | Maximum period, in milliseconds, between IIH PDUs
on multiaccess networks at this level for LANs.
The value at L1 is used as the period between
Hellos on L1L2 point-to-point circuits. Setting
this value at level 2 on an L1L2 point-to-point
circuit will result in an error of InconsistentValue.
This object follows the ResettingTimer behavior. |
Unite | milliseconds |
Syntaxe | Unsigned32 (10...600000) |
Module | ISIS-MIB (ietf) |
Nom | isisCircLevelHelloTimer |
Acces | readwrite |
Status | current |
Description | Maximum period, in milliseconds, between IIH PDUs
on multiaccess networks at this level for LANs.
The value at L1 is used as the period between
Hellos on L1L2 point-to-point circuits. Setting
this value at level 2 on an L1L2 point-to-point
circuit will result in an error of InconsistentValue.
This object follows the ResettingTimer behavior. |
Unite | milliseconds |
Syntaxe | Unsigned32 (10...600000) |