MIB Discovery
1930 modules enregistrés
Chemin
MIX : 1 (iso). 3 (org). 6 (dod). 1 (internet). 2 (mgmt). 1 (mib-2). 158 (dot3OamMIB). 1 (dot3OamObjects). 5 (dot3OamEventConfigTable). 1 (dot3OamEventConfigEntry). 3 (dot3OamErrSymPeriodThresholdHi)
OID : 1.3.6.1.2.1.158.1.5.1.3
TXT : iso. org. dod. internet. mgmt. mib-2. dot3OamMIB. dot3OamObjects. dot3OamEventConfigTable. dot3OamEventConfigEntry. dot3OamErrSymPeriodThresholdHi
Enfants
Pas d'enfants disponibles pour cet OID
Détails
OID1.3.6.1.2.1.158.1.5.1.3
Module DOT3-OAM-MIB (ietf)
Nomdot3OamErrSymPeriodThresholdHi
Accesreadwrite
Statuscurrent
Description The two objects dot3OamErrSymPeriodThresholdHi and dot3OamErrSymPeriodThresholdLo together form an unsigned 64-bit integer representing the number of symbol errors that must occur within a given window to cause this event. This is defined as dot3OamErrSymPeriodThreshold = ((2^32) * dot3OamErrSymPeriodThresholdHi) + dot3OamErrSymPeriodThresholdLo If dot3OamErrSymPeriodThreshold symbol errors occur within a window of dot3OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating that the threshold has been crossed in this window. The default value for dot3OamErrSymPeriodThreshold is one symbol errors. If the threshold value is zero, then an Event Notification OAMPDU is sent periodically (at the end of every window). This can be used as an asynchronous notification to the peer OAM entity of the statistics related to this threshold crossing alarm.
Unite2^32 symbols
SyntaxeUnsigned32
Module DOT3-OAM-MIB (Alcatel)
Nomdot3OamErrSymPeriodThresholdHi
Accesreadwrite
Statuscurrent
Description The two objects dot3OamErrSymPeriodThresholdHi and dot3OamErrSymPeriodThresholdLo together form an unsigned 64-bit integer representing the number of symbol errors that must occur within a given window to cause this event. This is defined as dot3OamErrSymPeriodThreshold = ((2^32) * dot3OamErrSymPeriodThresholdHi) + dot3OamErrSymPeriodThresholdLo If dot3OamErrSymPeriodThreshold symbol errors occur within a window of dot3OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be generated with an Errored Symbol Period Event TLV indicating that the threshold has been crossed in this window. The default value for dot3OamErrSymPeriodThreshold is one symbol errors. If the threshold value is zero, then an Event Notification OAMPDU is sent periodically (at the end of every window). This can be used as an asynchronous notification to the peer OAM entity of the statistics related to this threshold crossing alarm.
Unite2^32 symbols
SyntaxeUnsigned32