Description | The number of missing EndOfPacket indicators expected by the
frame assembly function.
This read-only counter is inactive when the PAF is
unsupported or disabled. Upon disabling the PAF, the counter
retains its previous value.
If a Clause 45 MDIO Interface to the PCS is present, then
this object maps to the 10P/2B PAF lost start of fragment
register.
Discontinuities in the value of this counter can occur at
re-initialization of the management system, and at other times
as indicated by the value of ifCounterDiscontinuityTime,
defined in IF-MIB. |