Description | An estimate of the equivalent loop's physical length in
meters, as perceived by the PME after the link is established.
An equivalent loop is a hypothetical 26AWG (0.4mm) loop with a
perfect square root attenuation characteristic, without any
bridged taps.
The value of 65535 is returned if the link is Down or
Initializing or the PME is unable to estimate the equivalent
length.
For a 10BASE-TL PME, if a Clause 45 MDIO Interface to the PME
is present, then this object maps to the 10P Electrical Length
register. |