OID | 1.3.6.1.2.1.18.8.5.1.5 |
Module | DECNET-PHIV-MIB (ietf) |
Nom | phivControlDyingBase |
Acces | readwrite |
Status | mandatory |
Description | This value represents the base priority to which a tributary is reset each time it has been polled. A separate base can be set for each of the indicated polling states. Base is a decimal integer in the range 0-255. If not set, the defaults are: active, 255; inactive, 0; and dying, 0. |
Syntaxe | Integer32 (0...255) |