MIB Discovery
1930 modules enregistrés
Chemin
MIX : 1 (iso). 3 (org). 6 (dod). 1 (internet). 2 (mgmt). 1 (mib-2). 88 (dismanEventMIB). 1 (dismanEventMIBObjects). 2 (mteTrigger). 3 (mteTriggerDeltaTable). 1 (mteTriggerDeltaEntry). 1 (mteTriggerDeltaDiscontinuityID)
OID : 1.3.6.1.2.1.88.1.2.3.1.1
TXT : iso. org. dod. internet. mgmt. mib-2. dismanEventMIB. dismanEventMIBObjects. mteTrigger. mteTriggerDeltaTable. mteTriggerDeltaEntry. mteTriggerDeltaDiscontinuityID
Enfants
Pas d'enfants disponibles pour cet OID
Détails
OID1.3.6.1.2.1.88.1.2.3.1.1
Module DISMAN-EVENT-MIB (CISCO)
NommteTriggerDeltaDiscontinuityID
Accesreadwrite
Statuscurrent
DescriptionThe OBJECT IDENTIFIER (OID) of a TimeTicks, TimeStamp, or DateAndTime object that indicates a discontinuity in the value at mteTriggerValueID. The OID may be for a leaf object (e.g. sysUpTime.0) or may be wildcarded to match mteTriggerValueID. This object supports normal checking for a discontinuity in a counter. Note that if this object does not point to sysUpTime discontinuity checking MUST still check sysUpTime for an overall discontinuity. If the object identified is not accessible the sample attempt is in error, with the error code as from an SNMP request. Bad object identifiers or a mismatch between truncating the identifier and the value of mteDeltaDiscontinuityIDWildcard result in operation as one would expect when providing the wrong identifier to a Get operation. The Get will fail or get the wrong object. If the value syntax of those objects is not usable, that results in an error that terminates the sample with a 'badType' error code.
SyntaxeObjectIdentifier
Module DISMAN-EVENT-MIB (ietf)
NommteTriggerDeltaDiscontinuityID
Accesreadwrite
Statuscurrent
DescriptionThe OBJECT IDENTIFIER (OID) of a TimeTicks, TimeStamp, or DateAndTime object that indicates a discontinuity in the value at mteTriggerValueID. The OID may be for a leaf object (e.g. sysUpTime.0) or may be wildcarded to match mteTriggerValueID. This object supports normal checking for a discontinuity in a counter. Note that if this object does not point to sysUpTime discontinuity checking MUST still check sysUpTime for an overall discontinuity. If the object identified is not accessible the sample attempt is in error, with the error code as from an SNMP request. Bad object identifiers or a mismatch between truncating the identifier and the value of mteDeltaDiscontinuityIDWildcard result in operation as one would expect when providing the wrong identifier to a Get operation. The Get will fail or get the wrong object. If the value syntax of those objects is not usable, that results in an error that terminates the sample with a 'badType' error code.
SyntaxeObjectIdentifier