MIB Discovery
1930 modules enregistrés
Chemin
MIX : 1 (iso). 3 (org). 6 (dod). 1 (internet). 2 (mgmt). 1 (mib-2). 95 (frsldMIB). 1 (frsldObjects). 1 (frsldPvcCtrlTable). 1 (frsldPvcCtrlEntry). 4 (frsldPvcCtrlStatus)
OID : 1.3.6.1.2.1.95.1.1.1.4
TXT : iso. org. dod. internet. mgmt. mib-2. frsldMIB. frsldObjects. frsldPvcCtrlTable. frsldPvcCtrlEntry. frsldPvcCtrlStatus
Enfants
Pas d'enfants disponibles pour cet OID
Détails
OID1.3.6.1.2.1.95.1.1.1.4
Module FRSLD-MIB (ietf)
NomfrsldPvcCtrlStatus
Accesreadwrite
Statuscurrent
DescriptionThe status of the current row. This object is used to add, delete, and disable rows in this table. When the status changes to active(1) for the first time, a row will also be added to the data table below. This row SHOULD not be removed until the status is changed to deleted. When this object is set to destroy(6), all associated sample and data table rows will also be deleted. When this object is changed from active(1) to any other valid value, the defined purge behavior will affect the data and sample tables. The rows added to this table MUST have a valid ifIndex and an ifType related to frame relay. Further, the reference points referred to by frsldPvcCtrlTransmitRP and frsldPvcCtrlReceiveRP MUST be supported (see the frsldRPCaps object). If at any point the row is not in the active(1) state and the DLCI no longer exists, the state SHOULD report notReady(3). The data in this table SHOULD persist through power cycles. The symantics of readiness for the rows still applies. This means that it is possible for a row to be reprovisioned as notReady(3) if the underlying DLCI does not persist.
SyntaxeRowStatus (SNMPv2-TC)