| OID | 1.3.6.1.3.37.1.3.1.1.8 |
| Module | ISIS-MIB (Alcatel) |
| Nom | isisCircLevelHelloTimer |
| Acces | readwrite |
| Status | current |
| Description | Maximum period, in milliseconds, between IIH PDUs on multiaccess networks at this level for LANs. The value at level 1 is used as the period between Hellos on point to point circuits. Setting this value at level 2 on a point to point circuit will result in an error of InconsistentValue. This object follows the resettingTimer behaviour. |
| Syntaxe | Integer32 (10...600000) |