MIB Discovery
1930 modules enregistrés
Chemin
MIX : 1 (iso). 3 (org). 6 (dod). 1 (internet). 4 (private). 1 (enterprises). 318 (apc). 1 (products). 1 (hardware). 1 (ups). 11 (upsState). 2 (upsAdvState). 3 (upsAdvStateDP300ESpecificFaults)
OID : 1.3.6.1.4.1.318.1.1.1.11.2.3
TXT : iso. org. dod. internet. private. enterprises. apc. products. hardware. ups. upsState. upsAdvState. upsAdvStateDP300ESpecificFaults
Enfants
Pas d'enfants disponibles pour cet OID
Détails
OID1.3.6.1.4.1.318.1.1.1.11.2.3
Module PowerNet-MIB (APC)
NomupsAdvStateDP300ESpecificFaults
Accesreadonly
Statusmandatory
DescriptionAn ASCII string containing the 64 flags representing the current active UPS specific faults for the Silcon DP300E UPS models. If the Network Card is unable to determine the values of the flags, this variable is set to 'UNKNOWN'. If the connected UPS does not use this variable, it is set to 'NOT SUPPORTED'. The flags are numbered from 1 to 64, and read from left to right. The bits are defined as follows: Flag 1: Peak Current Limiter Active Flag 2: Bypass Power Supply Fault Flag 3: Delta Current Limiter Active Flag 4: Fan Fault Flag 5: High DC warning Flag 6: Inverter Voltage Error Flag 7: Parallel Synchronization Error Flag 8: Second Power Supply Fault Flag 9: Internal Power Supply Fault Flag 10: Flag 11: Flag 12: Flag 13: Flag 14: Bypass Static Switch High Temperature Flag 15: High Battery Temperature Flag 16: Battery Weak Flag 17: Flag 18: System Locked in Operation Mode Flag 19: RAM1 Memory Write Error Flag 20: Memory Write Error Flag 21: Communication to VQ Bypass Lost Flag 22: Communication to VQ Output Lost Flag 23: Communication to DMU Lost Flag 24: Communication to Controller Lost Flag 25: Communication to Parallel IF Lost Flag 26: External Shutdown Accepted Flag 27: DC Capacitor Charge Error Flag 28: Communication to VQ Mains Lost Flag 29: Bypass Synchronization Error Flag 30: Charge Error Flag 31: SII Aux Input Activiated Flag 32: Flag 33: Blown Inverter Fuse Flag 34: Blown Rectifier Fuse Flag 35: Auxilliary 1 Fault Flag 36: Flag 37: Flag 38: Flag 39: Flag 40: Flag 41: Flag 42: Flag 43: Flag 44: Flag 45: Flag 46: High Temperature Charger Magnetic Flag 47: Flag 48: Battery Monitor Warning Flag 49: Battery Monitor Alarm Flag 50: Flag 51: Flag 52: Flag 53: TSM 1/2/3 Temperature Shutdown Flag 54: Charger 0/30 Temperature Warning Flag 55: Charger 0/30 Temperature Shutdown Flag 56: High Output Voltage Flag 57: SSW Temperature Over 90 Flag 58: Flag 59: Low Current Failure In AC Capacitors Flag 60: Flag 61: Advanced Battery Management Not Installed Flag 62: Flag 63: Flag 64:
SyntaxeDisplayString (RFC1213-MIB)