MIB Discovery
1930 modules enregistrés
Chemin
MIX : 1 (iso). 3 (org). 6 (dod). 1 (internet). 4 (private). 1 (enterprises). 318 (apc). 1 (products). 1 (hardware). 1 (ups). 5 (upsConfig). 2 (upsAdvConfig). 19 (upsAdvConfigOutputFreqRange)
OID : 1.3.6.1.4.1.318.1.1.1.5.2.19
TXT : iso. org. dod. internet. private. enterprises. apc. products. hardware. ups. upsConfig. upsAdvConfig. upsAdvConfigOutputFreqRange
Enfants
Pas d'enfants disponibles pour cet OID
Détails
OID1.3.6.1.4.1.318.1.1.1.5.2.19
Module PowerNet-MIB (APC)
NomupsAdvConfigOutputFreqRange
Accesreadwrite
Statusmandatory
DescriptionConfigure the output frequency tolerance range. unknown(1) indicates the output frequency is unknown. freqRangeAUTO(2) configure the output frequency range for automatic. freqRange60Var1(3) configure the output frequency range for 60 +/- 0.1 Hz freqRange60Var3(4) configure the output frequency range for 60 +/- 3.0 Hz freqRange50Var1(5) configure the output frequency range for 50 +/- 0.1 Hz freqRange50Var3(6) configure the output frequency range for 50 +/- 3.0 Hz freqRange60Var10(7) configure the output frequency range for 60 +/- 10 Hz freqRange50Var10(8) configure the output frequency range for 50 +/- 10 Hz freqRange60Var1dot0(9) configure the output frequency range for 60 +/- 1.0 Hz freqRange50Var1dot0(10) configure the output frequency range for 50 +/- 1.0 Hz freqRange50Pct0dot5(11) configure the output frequency range for 50 Hz +/- 0.5 % freqRange50Pct1(12) configure the output frequency range for 50 Hz +/- 1.0 % freqRange50Pct2(13) configure the output frequency range for 50 Hz +/- 2.0 % freqRange50Pct4(14) configure the output frequency range for 50 Hz +/- 4.0 % freqRange50Pct6(15) configure the output frequency range for 50 Hz +/- 6.0 % freqRange50Pct8(16) configure the output frequency range for 50 Hz +/- 8.0 % freqRange60Pct0dot5(17) configure the output frequency range for 60 Hz +/- 0.5 % freqRange60Pct1(18) configure the output frequency range for 60 Hz +/- 1.0 % freqRange60Pct2(19) configure the output frequency range for 60 Hz +/- 2.0 % freqRange60Pct4(20) configure the output frequency range for 60 Hz +/- 4.0 % freqRange60Pct6(21) configure the output frequency range for 60 Hz +/- 6.0 % freqRange60Pct8(22) configure the output frequency range for 60 Hz +/- 8.0 % For a list of allowed values and conditions when variable can be set by your UPS model, see the UPS User's Manual.
SyntaxeEnumeration (1-unknown, 2-freqRangeAUTO, 3-freqRange60Var1, 4-freqRange60Var3, 5-freqRange50Var1, 6-freqRange50Var3, 7-freqRange60Var10, 8-freqRange50Var10, 9-freqRange60Var1dot0, 10-freqRange50Var1dot0, 11-freqRange50Pct0dot5, 12-freqRange50Pct1, 13-freqRange50Pct2, 14-freqRange50Pct4, 15-freqRange50Pct6, 16-freqRange50Pct8, 17-freqRange60Pct0dot5, 18-freqRange60Pct1, 19-freqRange60Pct2, 20-freqRange60Pct4, 21-freqRange60Pct6, 22-freqRange60Pct8)