OID | 1.3.6.1.4.1.351.110.3.17.4.15 |
Module | CISCO-VISM-MODULE-MIB (CISCO) |
Nom | vismBearerContinuityTimer |
Acces | readwrite |
Status | current |
Description | This object specifies the co4 (bearer continuity) timer in millisecs. The timer will be started in the terminating/originating gateway for a duration as specified in this MIB object when a co3 message is sent from the terminating/originating gateway to the originating/terminating gateway. If the terminating/originating gateway does not receive co4 as an acknowledgement from the originating/termintaing gateway and the timer expires, gateway initiated DLCX is sent to the call agent from the terminating/originating gateway. This object is applicable when the call agent feature is available. |
Syntaxe | Integer32 (0...10000) |