OID | 1.3.6.1.4.1.351.110.4.7.1.1.22 |
Module | CISCO-VISM-DSX0-MIB (CISCO) |
Nom | ds0CasGaurdTime |
Acces | readwrite |
Status | current |
Description | The gaurd time is the duration between the end of one call and the start of next call. This object specifies what should be such a duration. All state changes from the PBX are ignored for this duration. After receiving DLCX, this timer will be started for a period as configured in this object, and will not honor any off-hook events before the expiration of this timer. This object cannot be configured if the signaling type for the line to which this ds0 belongs is non cas. For a cas line this object CAN only be configured only after associating this ds0 with an endpoint This object will be applicable if ds0CasParameterSource has a value of mibValue (2). The allowed range for this object is 10..1000. |
Unite | milliseconds |
Syntaxe | Integer32 (0...65535) |