Description | Indicates whether this MPC should auto-configure
the next time it is (re-)initialized.
During the (re-)initialization of this MPC, if
the mode is automatic(1), the LECS is contacted and
requests are made for all MPC-p* parameters.
Otherwise, if the mode is manual(2), the values of the
configuration parameters are obtained from the
mpcConfigTableand the mpcProtocolTable. In other words, when
the MPC is first initialized, it can use the default or
configured values from the mpcConfigTable and
mpcProtocolTable. If the mode is manual (2), no further
action is required. If the mode is automatic (1), then
the LECS should be contacted and all available MPC-p1
to MPC-p6 parameters would be retrieved.
These parameters would then overwrite the existing MPC-p1 to
MPC-p6 parameters. The actual values are reflected in the
mpcActualTable. |