Description | Statistics associated to the DTI client state machine.
This table contains counters of the most significant
DTI finite State machine transitions and states as
reported in the DTI Client Frame.
Below is a description of the State Transition and
counters supported (not all State Transitions need
object definitions):
T1: Warmup to Free-run
Normally once after the clock warms up.
Rather than defining a counter for this
state transition, the managed system updates
the object ifDiscontinuity with the time when
the clock performs a transition to Free-run
State
T2: Free-run to Fast
Not defined counter. T2 = T3 + 1
T3: Fast to Free-run (dtiProtocolClientFsmStatsT3Count)
T4: Fast to Normal (dtiProtocolClientFsmStatsT4Count)
Counts the times the clock enters to the normal
mode of operation.
T5: Normal to Bridging
Not defined counter. T5 = T6 + T7
T6: Bridging to Normal (dtiProtocolClientFsmStatsT6Count)
T7: Bridging to Holdover (dtiProtocolClientFsmStatsT7Count)
T8: Holdover to Fast
No counter defined.
If DTI Client State is Holdover, T8 = T7 - 1
other DTI Client State, T8 = T7
This table also includes the active time the DTI client is
in Normal state(dtiProtocolClientFsmStatsNormalActiveTime)
and Holdover state
(dtiProtocolClientFsmStatsHoldoverActiveTime). |