Description | If true, the local OAM entity should attempt to indicate a
critical event via the OAMPDU flags to its peer OAM entity
when a critical event occurs. The exact definition of a
critical event is implementation dependent. If the system
does not support critical event capability, setting this
object has no effect, and reading the object should always
result in 'false'.
By default, this object should have the value true for
Ethernet like interfaces that support OAM. If the OAM layer
does not support event notifications (as indicated via the
cdot3OamFunctionsSupported attribute), this value is ignored. |