Description | This object allows the management client to set the
clock rate across the client side interface.
Due to hardware limitations, all values may not be supported.
The default value of this object depends on the value of the
cmPhyIfProtocol object. When the value of the cmPhyIfProtocol
object is reset, the value of this object will be
automatically set to the default for that protocol.
In case of protocols that support multiple rates,
the default value of this object will be the lowest rate
possible for that protocol. For example, if the value
of cmPhyIfProtocol is set to 'sonet', the default value
of cmPhyIfClockRate is set to the OC-3 rate of 155520 kHz.
If a non-default value is desired, then this object must
be set after the cmPhyIfProtocol object has been reset.
This object must be set to a supported clock rate when
setting cmPhyIfProtocol to 'unknown'.
In 2R mode of operation, this object is not applicable
and will have a default value of 0.
The value of this object cannot be modified when the
cmPhyIfMonitor object is set to 'true' for that interface.
Also, this object is not applicable to trunk side interfaces. |