OID | 1.3.6.1.4.1.9.9.136.1.8.2.1.14 |
Module | CISCO-WIRELESS-IF-MIB (CISCO) |
Nom | cwrTlRowStatus |
Acces | readwrite |
Status | current |
Description | This object may be used to create or delete a timeline control specification. Once created data sampling starts based on the value of cwrTlAction. The data capture depends on the value of cwrTlThreshIndex. The actual data is collected based on the cwrTlThreshIndex, if cwrTlThreshIndex is 0 then there is no stop trigger associated with this timeline and the data samples are captured and returned immediately. If cwrTlThresIndex is not 0, then the data samples are captured when the threshold fires. |
Syntaxe | RowStatus (SNMPv2-TC) |