Description | This object specifies a severity threshold governing the
generation of syslog messages corresponding to alarms. For
example, if the value of this object is set to 'major', then
the agent generates these a syslog message if and only if the
severity of the alarm being indicated is 'major' or 'critical'.
The value of '0' disables the generation of syslog messages
corresponding to alarms.
Observe that this setting overrides the value of the
ceAlarmFilterSyslogEnabled object.
This object affects syslog message generation only; that is, it
does not have an effect on monitoring, history logging, and
generation of notifications. |