Description | A table of Round Trip Time (RTT) monitoring history
definitions.
The definitions in this table control what and how many
entries will be placed into the
rttMonHistoryCollectionTable.
The history collection table is a rollover table. When
the rttMonHistoryAdminNumLives index value exceeds its
value defined in this table, the oldest corresponding
'lives' group will be deleted and will be replaced with
the new 'lives' group. All other indices will only fill
to their maximum size.
NOTE: The maximum size of this table is defined to be
the product of the rttMonCtrlAdminIndex times
rttMonHistoryAdminNumLives times
rttMonHistoryAdminNumBuckets times
rttMonHistoryAdminNumSamples.
NOTE WELL: Each of the 'Num' objects values in this
have a special behavior. When one of the
objects is set to a value larger than the
Rtt application can support the set will
succeed, but the resultant value will
be set to the applications maximum value.
The setting management station must reread
this object to verify the actual value.
NOTE: this table is not applicable to http and jitter
probes |