OID | 1.3.6.1.4.1.9.9.597.1.3.1.1.7 |
Module | CISCO-CONTENT-SERVICES-MIB (CISCO) |
Nom | ccsAdControlNotifEnabled |
Acces | readwrite |
Status | current |
Description | This object controls the generation of the notifications for the AdControl. The alarm and clear notifications are enabled when ccsAdControlNotifEnabled is set to 'true'. The AdControl will start a timer with the interval controlled by ccsAdControlAlarmUpdateTimer for each event. An alarm notification will be generated if the error exceeds the alarm threshold within the interval and no such alarm has been raised yet. The timer will be restarted after an alarm notification is generated. When the timer expires, a clear notification will be generated if the error is equal to or less than the clear threshold and the alarm exists. 'true' Indicates that the notifications are enabled. 'false' Indicates that notifications are disabled. |
Syntaxe | TruthValue (SNMPv2-TC) |