Description | This table lists the standing conditions monitored by the
device. The table groups descriptions for standing conditions
into condition profiles.
The figure below illustrates the relationship between a flow
monitor and a conditions profile. Observe that a conditions
profile can contain the descriptions for the standing conditions
monitored for more than one flow monitor. In this case, the
instance of cfmFlowMonitorConditionsProfile for each of these
flow monitors would reference the same conditions profile.
+------------------------------------------------+
| flow monitor 1 |
| |
| cfmFlowMonitorConditionsProfile.1 = 42 -----+ |
| | |
| cfmFlowMonitorConditions.1 | |
| N 2 1 0 | |
| +-+-...-+-+-+-+ | |
| | | | | | | | |
| +-+-...-+-+-+-+ | |
| ^ ^ ^ ^ | |
| | | | | | |
+--|-------|-|-|------------------------------|--+
| | | | |
| | | | V
| | | | +-----------------------------+
| | | | | conditions profile 42 |
| | | | | +-------------------------+ |
| | | +-----------------| cfmConditionsDescr.42.0 | |
| | | | +-------------------------+ |
| | | | +-------------------------+ |
| | +-------------------| cfmConditionsDescr.42.1 | |
| | | +-------------------------+ |
| | | +-------------------------+ |
| +---------------------| cfmConditionsDescr.42.2 | |
| | +-------------------------+ |
| | : |
| | : |
| | +-------------------------+ |
+-----------------------------| cfmConditionsDescr.42.N | |
| +-------------------------+ |
+-----------------------------+
The figure below illustrates the relationship between a traffic
flow and a conditions profile. Observe that a conditions
profile can contain the descriptions for the standing conditions
monitored for more than one traffic flow. In this case, the
instance of cfmFlowMetricsConditionsProfile for each of these
traffic flows would reference the same conditions profile.
+------------------------------------------------+
| traffic flow 201 |
| |
| cfmFlowMetricsConditionsProfile.1.201 = 54 -+ |
| | |
| cfmFlowMetricsConditions.1.201 | |
| N 2 1 0 | |
| +-+-...-+-+-+-+ | |
| | | | | | | | |
| +-+-...-+-+-+-+ | |
| ^ ^ ^ ^ | |
| | | | | | |
+--|-------|-|-|------------------------------|--+
| | | | |
| | | | V
| | | | +-----------------------------+
| | | | | conditions profile 54 |
| | | | | +-------------------------+ |
| | | +-----------------| cfmConditionsDescr.54.0 | |
| | | | +-------------------------+ |
| | | | +-------------------------+ |
| | +-------------------| cfmConditionsDescr.54.1 | |
| | | +-------------------------+ |
| | | +-------------------------+ |
| +---------------------| cfmConditionsDescr.54.2 | |
| | +-------------------------+ |
| | : |
| | : |
| | +-------------------------+ |
+-----------------------------| cfmConditionsDescr.54.N | |
| +-------------------------+ |
+-----------------------------+
The figure below illustrates the relationship between the
description of a standing condition and an alarm group if the
standing condition indicates that the device aggregates the
standing condition into an alarm group (i.e., the corresponding
instance of cfmConditionAlarm is 'grouped').
+-----------------------------------------+
| conditions profile 42 |
| +-------------------------------------+ |
| | cfmConditionAlarm.42.9 = 'grouped' |<-------+
| | cfmConditionAlarmGroup.42.9 = 4 -+ | | |
| +----------------------------------|--+ |<--+ |
| | | | |
+------------------------------------|----+ | |
V | |
+-----------------------------------------+ | |
| alarm group 4 | | |
| | | |
| cfmAlarmGroupConditionsProfile.4 = 42 ------+ |
| cfmAlarmGroupConditionId.4 = 9 ----------------+
| |
+-----------------------------------------+ |