Description | This object indicates which metrics are valid for the traffic
flow:
'expectedPkts'
If this bit is set to '1', then the corresponding
instance of cfmRtpMetricsExpectedPkts is valid.
'lostPkts'
If this bit is set to '1', then the corresponding
instance of cfmRtpMetricsLostPkts is valid.
'lossFraction'
If this bit is set to '1', then the corresponding
instances of cfmRtpMetricsFracScale,
cfmRtpMetricsFracPrecision, and cfmRtpMetricsFrac are
valid.
'lossIntervals'
If this bit is set to '1', then the corresponding
instance of cfmRtpMetricsLIs is valid.
'avgLossIntervalDuration'
If this bit is set to '1', then the corresponding
instances of cfmRtpMetricsAvgLDScale,
cfmRtpMetricsAvgLDPrecision, and cfmRtpMetricsAvgLD are
valid.
'avgLossDistance'
If this bit is set to '1', then the corresponding
instance of cfmRtpMetricsAvgLossDistance is valid.
'jitter'
If this bit is set to '1', then the corresponding
instances of cfmRtpMetricsJitterScale,
cfmRtpMetricsJitterPrecision, and cfmRtpMetricsJitter
are valid. |